Polycom, Inc. VSX 7000e and VSX 8000 (Firmware version: 8.5.0.2) FIPS 140-2 Non-Proprietary Security Policy Level 1 Validation Document Version 1.0 Prepared for: Prepared by: Polycom, Inc. Corsec Security, Inc. 4750 Willow Road 10340 Democracy Lane, Suite 201 Pleasanton, CA 94588-2708 Fairfax, VA 22030 Phone: 1.800.POLYCOM Phone: (703) 267-6050 Fax: (925) 924-6100 Fax: (703) 267-6810 http://www.polycom.com http://www.corsec.com © 2007 Polycom, Inc. ­ This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Revision History Version Modification Date Modified By Description of Changes 1.0 2007-06-15 Xiaoyu Ruan Release version Polycom VSX 7000e and VSX 8000 Page 2 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Table of Contents 0 INTRODUCTION ...............................................................................................................................................5 0.1 PURPOSE .........................................................................................................................................................5 0.2 REFERENCES ...................................................................................................................................................5 0.3 DOCUMENT ORGANIZATION ...........................................................................................................................5 1 VSX 7000E AND VSX 8000 ................................................................................................................................6 1.1 OVERVIEW......................................................................................................................................................6 1.2 MODULE SPECIFICATIONS ..............................................................................................................................6 1.3 MODULE INTERFACES ....................................................................................................................................8 1.4 ROLES AND SERVICES...................................................................................................................................15 1.4.1 Crypto-Officer Role .............................................................................................................................15 1.4.2 User Role .............................................................................................................................................16 1.4.3 Authentication......................................................................................................................................16 1.5 PHYSICAL SECURITY ....................................................................................................................................16 1.6 OPERATIONAL ENVIRONMENT ......................................................................................................................16 1.7 CRYPTOGRAPHIC KEY MANAGEMENT ..........................................................................................................16 1.7.1 Key Generation....................................................................................................................................17 1.7.2 Key Input/Output .................................................................................................................................17 1.7.3 Key Storage..........................................................................................................................................18 1.7.4 Key Zeroization....................................................................................................................................18 1.8 SELF-TESTS ..................................................................................................................................................18 1.9 DESIGN ASSURANCE.....................................................................................................................................18 2 SECURE OPERATION....................................................................................................................................19 2.1 CRYPTO-OFFICER GUIDANCE .......................................................................................................................19 2.1.1 Initialization.........................................................................................................................................19 2.1.2 Management ........................................................................................................................................19 2.2 USER GUIDANCE ..........................................................................................................................................20 3 ACRONYMS......................................................................................................................................................22 Table of Figures FIGURE 1 - VSX 3000.....................................................................................................................................................6 FIGURE 2 - VSX 5000.....................................................................................................................................................7 FIGURE 3 - VSX 7000S ...................................................................................................................................................7 FIGURE 4 - VSX 7000E ...................................................................................................................................................7 FIGURE 5 - VSX 8000.....................................................................................................................................................8 FIGURE 6 - VSX 3000 CONNECTOR PANEL ....................................................................................................................9 FIGURE 7 - VSX 5000 BACK PANEL .............................................................................................................................10 FIGURE 8 - VSX 7000E BACK PANEL ...........................................................................................................................11 FIGURE 9 - VSX 7000S BACK PANEL ...........................................................................................................................13 FIGURE 10 - VSX 8000 BACK PANEL ...........................................................................................................................14 Table of Tables TABLE 1 - SECURITY LEVEL PER FIPS 140-2 SECTION ...................................................................................................8 TABLE 2 - MAPPING OF FIPS 140-2 LOGICAL INTERFACES TO VSX 7000E AND VSX 8000 INTERFACES .......................9 TABLE 3 - MAPPING OF FIPS 140-2 LOGICAL INTERFACES TO VSX 5000 INTERFACES ................................................10 Polycom VSX 7000e and VSX 8000 Page 3 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 TABLE 4 - MAPPING OF FIPS 140-2 LOGICAL INTERFACES TO VSX 7000E INTERFACES ..............................................12 TABLE 5 - MAPPING OF FIPS 140-2 LOGICAL INTERFACES TO VSX 7000S INTERFACES ..............................................13 TABLE 6 - MAPPING OF FIPS 140-2 LOGICAL INTERFACES TO VSX 8000 INTERFACES ................................................14 TABLE 7 - MAPPING OF CRYPTO-OFFICER'S SERVICES TO INPUTS, OUTPUTS, CRITICAL SECURITY PARAMETERS (CSPS), AND ACCESS CONTROL ...........................................................................................................................15 TABLE 8 - MAPPING OF USER'S SERVICES TO INPUTS, OUTPUTS, CSPS, AND ACCESS CONTROL .................................16 TABLE 9 - LIST OF CRYPTOGRAPHIC KEYS, CRYPTOGRAPHIC KEY COMPONENTS, AND CSPS .....................................17 TABLE 10 - LED/POWER BUTTON LIGHT DESCRIPTION ...............................................................................................20 TABLE 11 - BRI NETWORK INTERFACE LEDS ..............................................................................................................21 TABLE 12 - PRI NETWORK INTERFACE LEDS ..............................................................................................................21 TABLE 13 - V.35/RS-449/RS-530 NETWORK INTERFACE LEDS ..................................................................................21 TABLE 14 - ACRONYMS ................................................................................................................................................22 Polycom VSX 7000e and VSX 8000 Page 4 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 0 Introduction 0.1 Purpose This is a non-proprietary Cryptographic Module Security Policy for the VSX 7000e and VSX 8000 from Polycom, Inc.. This Security Policy describes how the VSX 7000e and VSX 8000 meet the security requirements of FIPS 140-2 and how to run the module in a secure FIPS 140-2 mode. This policy was prepared as part of the Level 1 FIPS 140-2 validation of the module. FIPS 140-2 (Federal Information Processing Standards Publication 140-2 ­ Security Requirements for Cryptographic Modules) details the U.S. Government requirements for cryptographic modules. More information about the FIPS 140-2 standard and validation program is available on the National Institute of Standards and Technology (NIST) Cryptographic Module Validation Program (CMVP) website at: http://csrc.nist.gov/cryptval/ The VSX 7000e and VSX 8000 are referred to in this document as the VSX systems, the hardware modules, the cryptographic modules, or the modules. 0.2 References This document deals only with operations and capabilities of the module in the technical terms of a FIPS 140-2 cryptographic module security policy. More information is available on the module from the following sources: · The Polycom website (http://polycom.com) contains information on the full line of products from Polycom. · The CMVP website (http://csrc.nist.gov/cryptval/) contains contact information for answers to technical or sales-related questions for the module. 0.3 Document Organization The Security Policy document is one document in a FIPS 140-2 Submission Package. In addition to this document, the Submission Package contains: · Vendor Evidence document · Finite State Machine · Other supporting documentation as additional references This Security Policy and the other validation submission documentation were produced by Corsec Security, Inc. under contract to Polycom. With the exception of this Non-Proprietary Security Policy, the FIPS 140-2 Validation Documentation is proprietary to Polycom and is releasable only under appropriate non-disclosure agreements. For access to these documents, please contact Polycom. Polycom VSX 7000e and VSX 8000 Page 5 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 1 VSX 7000e and VSX 8000 1.1 Overview Founded in 1990, Polycom is the only company delivering end-to-end rich media collaborative applications for voice, video, data and the web. Polycom has a wide range of products from desktop and mobile personal systems to room systems to the network core. Polycom's full range of high-quality voice and video communications endpoints, video management software, web conferencing software, and multipoint conferencing enable organizations of all sizes to increase productivity and agility. Polycom delivers business value by cutting costs, simplifying system management, fostering real time collaboration and decision making, and improving relationships with employees, customers and partners. The Polycom VSX products are state of the art video-conferencing nodes. These systems provide video- conferencing facilities using all the popular telecommunication protocols such as H.320 H.323, and Session Initiation Protocol (SIP) and include support of Integrated Services Digital Network (ISDN), Primary rate and Basic rate as well as serial interfaces for V.35, RS-499 and RS-530. 1.2 Module Specifications The VSX systems feature a variety of models ranging from desktop systems (VSX 3000) to set top appliance systems (VSX 5000, VSX 7000s) to rack mounted systems (VSX 7000e, VSX 8000). All of the models provide top-performance video processing and feature high-performance BSP-15 processors from Equator with 128 MB SDRAM. The VSX 3000 is an all-in-one desktop system that includes built-in camera, LCD screen, speakers, and microphone. This model interfaces with an Internet Protocol (IP) network with LAN cable and to ISDN S/T lines with BRI cables, and includes a separate power supply connector. The VSX 3000 is pictured below: Figure 1 - VSX 3000 The VSX 5000 is an entry-level compact set-top system with built in camera as shown below in Figure 2. The VSX 5000 supports an external microphone for audio input, and can be connected to an IP network with a LAN cable. A monitor either VGA or NTSC/PAL can be connected to the VSX 5000 using the supplied audio/video cables, and a separate power cable connects the device to its power supply. Polycom VSX 7000e and VSX 8000 Page 6 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Figure 2 - VSX 5000 The VSX 7000s is another set-top appliance which provides for a mechanical pan, tilt, zoom camera. The VSX 7000s supports H.323 networks with a internal NIC support 10/100mbps.. The VSX 7000 supports a subwoofer into which the optional Network Interface Card to support ISDN, V.35, RS-499 or RS-530 interfaces. . The VSX 7000s uses an external microphone array and has an internal audio reproduction system. The VSX 7000s is standard with dual video display output support and can support VGA, S-video or composite as the main monitor and the same options for the 2nd monitor when the main monitor is not VGA. Figure 3 - VSX 7000s The VSX 7000e and VSX 8000 models are rack-mounted systems as depicted in Figure 4 and Figure 5 below. The VSX 7000e is a video component system designed for medium-sized conferencing rooms, while the VSX 8000 system is a compact component system for custom integrators. These models support connections with monitors the same as the VSX 7000s and third-party cameras through standard S-video interfaces. The VSX 7000e and VSX 8000 models provide connections for external audio input and output, LAN ports, telephone jacks, and power supplies. There is an internal slot in the chassis to support ISDN, V.35, RS-499 or RS-530 interfaces. Figure 4 - VSX 7000e Polycom VSX 7000e and VSX 8000 Page 7 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Figure 5 - VSX 8000 Per FIPS PUB 140-2, the VSX 7000e and VSX 8000 are classified as multi-chip standalone cryptographic modules and validated at the following FIPS 140-2 Section levels: Table 1 - Security Level Per FIPS 140-2 Section Section Section Title Level 1 Cryptographic Module Specification 1 2 Cryptographic Module Ports and Interfaces 1 3 Roles, Services, and Authentication 1 4 Finite State Model 1 5 Physical Security 1 6 Operational Environment N/A 7 Cryptographic Key Management 1 8 EMI/EMC 1 9 Self-tests 1 10 Design Assurance 1 11 Mitigation of Other Attacks N/A 1.3 Module Interfaces The VSX 7000e and VSX 8000 are multi-chip standalone modules that meet overall level 1 FIPS 140-2 requirements. The cryptographic boundaries of the VSX 7000e and VSX 8000 are defined by the hard plastic or metal covers that include all the hardware and software components as shown in figures Figure 1 through Figure 5. Ports and interfaces on the module can be categorized as the following FIPS 140-2 logical interfaces: · Data Input Interface · Data Output Interface · Control Input interface · Status Output Interface Ports and interfaces of the VSX 3000 system are shown in Figure 6 below. The ports on the module's connector panel are listed below, and mapped to logical interfaces in Table 2 below. · BRI connectors ­ For ISDN calls · Stereo connector ­ For headphones or desktop speakers · Composite video connector ­ Video input to the system from camera or VCR/DVD · Audio connector ­ Audio input to the system from VCR/DVD · LAN connector ­ For IP calls, VSX Web, and remote management Polycom VSX 7000e and VSX 8000 Page 8 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 · Power connector ­ For power supply · Power switch for the codec ­ (one of three) · VGA connector ­ For Personal Computer (PC) to use system as a computer monitor and for passing the video image from the VGA input connector to a display device · LCD Screen ­ Screen for video conferencing · IR Sensor ­ Input from IR sensor · Speaker ­ Built-in speaker · Camera ­ Input for video conferencing · Microphone ­ Built-in microphone · LED ­ LEDs indicate system status Figure 6 - VSX 3000 Connector Panel The VSX 3000 physical interfaces are located under the system as depicted in Section 2 of the Administrator's Guide for the VSX Series, which lists on page one and two the connection cables required for the system. The following table maps VSX 3000 interfaces with FIPS 140-2 logical interfaces: Table 2 - Mapping of FIPS 140-2 Logical Interfaces to VSX 7000e and VSX 8000 Interfaces FIPS 140-2 Logical Interface VSX 7000e and VSX 8000 Port/Interface Data Input BRI connectors, Composite video connector, LAN connector, VGA connector, Audio Connector, Microphone, Camera Data Output BRI connectors, Stereo connector, LAN connector, LCD Screen, Speaker Control Input LAN connector, IR Sensor, Power switch Status Output LAN connector, LCD Screen, LEDs Power Power connector The following is the list of ports and interfaces of the VSX 5000 system and Figure 7 below shows the ports on module's back panel. · Power connector ­ For power supply · LAN connector ­ For IP calls, VSX Web, and remote management Polycom VSX 7000e and VSX 8000 Page 9 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 · Conference link connector ­ For microphone pod, SoundStation VTX 1000, or Visual Concert VSX · VGA connector ­ VGA connector for input and passes the video image for monitor or projector · VCR/DVD inputs ­ For VCR/DVD to play content into calls · Power switch ­ To power up or down the device · Audio connectors ­ For main monitor audio, or for external speaker system · S-Video Connector ­ S-Video output for monitor · Serial port ­ RS-232 port for RS-232 device · IR Sensor ­ Input from IR sensor · Speaker ­ Built-in speaker · Camera ­ Input for video conferencing · LED ­ LEDs indicate system status Figure 7 - VSX 5000 Back Panel Section 1 of the Administrator's Guide for the VSX Series lists the connection cables required for the system. The Following table maps VSX 5000 interfaces with FIPS 140-2 logical interfaces. Table 3 - Mapping of FIPS 140-2 Logical Interfaces to VSX 5000 Interfaces FIPS 140-2 Logical Interface VSX 7000e and VSX 8000 Port/Interface Data Input LAN connector, VGA connector, VCR/DVD inputs, Conference link connector, Serial Port, Camera Data Output LAN connector, VGA connector, Audio connectors, S-Video Connector, Serial Port, Conference link connector, Speaker Control Input Conference link connector, LAN connector, Serial Port, IR Sensor, Power switch Status Output VGA connector, S-Video connector, LAN connector, Serial Port, Conference link connector, LEDs Power Power connector Polycom VSX 7000e and VSX 8000 Page 10 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 The following is the list of ports and interfaces for the VSX 7000e system and Figure 8 below shows the ports on module's back panel. · Network interface bay ­ For network interface module (for BRI, PRI, and V.35/RS-449/RS-530 connection) · VCR/DVD connector ­ Play VCR/DVD content into calls or record the calls to VCR/DVD · Audio connector ­ Input to system from ImageShare II and computer, or outputs to external speaker · Serial ports ­ RS-232 port for touch panel, camera control, or other RS-232 devices · S-Video connector ­ Input to system from camera or output for S-Video monitor · Analog phone connector ­ For analog phone line · Camera 1 control connector ­ For camera 1 PTZ control · VGA connector ­ Input to system for ImageShare II and computer VGA, or outputs to VGA monitor and projector · LAN connector ­ For IP calls, VSX Web, and remote management · Conference link connector ­ For microphone pod, SoundStation VTX 1000, or Visual Concert VSX · IR Sensor ­ Input from IR sensor · Power button ­ Controls power and provides system status · LED ­ LEDs indicate system status · Power connector ­ For power cord Figure 8 - VSX 7000e Back Panel Polycom VSX 7000e and VSX 8000 Page 11 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Section 1 of the Administrator's Guide for the VSX Series lists the connection cables required for the VSX 7000e system. The following table maps VSX 7000e interfaces with FIPS 140-2 logical interfaces. Table 4 - Mapping of FIPS 140-2 Logical Interfaces to VSX 7000e Interfaces FIPS 140-2 Logical Interface VSX 7000e and VSX 8000e Port/Interface Data Input Network interface bay, VCR/DVD connector, Audio connector, Serial ports, S-Video connector, Analog phone connector, VGA connector, LAN connector, Conference link connector Data Output Network interface bay, VCR/DVD connector, Audio connector, Serial ports, S-Video connector, Analog phone connector, VGA connector, LAN connector, Conference link connector Control Input Network interface bay, Serial ports, Camera 1 control connector, LAN connector, Conference link connector, IR Sensor, Power button Status Output Network interface bay, Serial ports, LAN connector, Conference link connector, Power button, LEDs Power Power connector The following list provides the ports and interfaces of the VSX 7000s system and Figure 9 below shows the ports on module's back panel. · Power connector ­ Houses power for subwoofer and optional network interface module (for BRI, PRI, and V.35/RS-449/RS-530 connection) · LAN connector ­ For IP calls, VSX Web, and remote management · Conference link connector ­ For microphone pod, SoundStation VTX 1000, or Visual concert VSX · VGA connector ­ Output from system for VGA monitor or projector · VCR/DVD connector ­ Play VCR/DVD connect into calls or record call content · Power switch · S-Video connector ­ Input from camera or output to S-Video monitor · Audio connector ­ Output from system for external speaker system · Serial RS-232 port ­ RS-232 port for touch panel, camera control, or other RS-232 device · IR Sensor ­ Input from IR sensor · Speaker ­ Built-in speaker · Camera ­ Input for video conferencing · LED ­ LEDs indicate system status Polycom VSX 7000e and VSX 8000 Page 12 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Figure 9 - VSX 7000s Back Panel Section 1 of the Administrator's Guide for the VSX Series lists the connection cables required for the system. The following table maps VSX 7000s interfaces with FIPS 140-2 logical interfaces. Table 5 - Mapping of FIPS 140-2 Logical Interfaces to VSX 7000s Interfaces FIPS 140-2 Logical Interface VSX 7000e and VSX 8000s Port/Interface Data Input LAN connector, Conference link connector, VCR/DVD connector, Serial port, S-Video connector, Camera Data Output LAN connector, VGA connector, VCR/DVD connector, S-Video connector, Audio connector, Serial port, Conference link connector, Speaker Control Input LAN connector, Serial port, Conference link connector, IR Sensor, Power switch Status Output LAN connector, VGA connector, Serial port, Conference link connector, LEDs Power Power connector The following is the list of ports and interfaces of the VSX 8000 system and Figure 10 below shows the ports on module's connector panel. · Network interface bay ­ For network interface module (for BRI, PRI, and V.35/RS-449/RS-530 connection) · Balanced Audio connector ­ Input for mixed or powerful microphones or output for external audio equipment · VCR/DVD connector ­ Play VCR/DVD content into calls or record the calls to VCR/DVD · Serial ports ­ RS-232 port for touch panel, camera control, or other RS-232 device · Monitor 1Y and C ­ output for main monitor · S-Video connector ­ Input to system from camera or output for S-Video monitor · Audio connector ­Output to external speaker · VGA connector ­ Input to system for ImageShare II and computer VGA, or outputs to VGA monitor and projector · LAN connector ­ For IP calls, VSX Web, and remote management · Conference link connector ­ For microphone pod, SoundStation VTX 1000, or Visual Concert VSX · IR Sensor ­ Input from external IR sensor Polycom VSX 7000e and VSX 8000 Page 13 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 · Analog phone connector ­ For analog phone line · Camera 1 control connector ­ For camera 1 PTZ control · Camera 1Y and C ­ Input from main camera · IR Sensor ­ Input from IR sensor · Power button ­ Controls power and provides system status · LED ­ LEDs indicate system status · Power connector ­ For power cord Figure 10 - VSX 8000 Back Panel Section 1 of the Administrator's Guide for the VSX Series lists the connection cables required for the system. The following table maps VSX 8000 interfaces with FIPS 140-2 logical interfaces. Table 6 - Mapping of FIPS 140-2 Logical Interfaces to VSX 8000 Interfaces FIPS 140-2 Logical Interface VSX 7000e and VSX 8000 Port/Interface Data Input Network interface bay, Balanaced Audio connector, VCR/DVD connector, Serial port, S-Video connector, VGA connector, LAN connector, Conference link connector, Analog phone connector, Camera 1Y and C Data Output Network interface bay, Balanaced Audio connector, VCR/DVD connector, Serial port, Monitor 1Y and C, S-Video connector, Audio connector, VGA connector, LAN connector, Analog phone connector, Conference link connector Polycom VSX 7000e and VSX 8000 Page 14 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 FIPS 140-2 Logical Interface VSX 7000e and VSX 8000 Port/Interface Control Input Serial port, LAN connector, IR Sensor, Camera 1 control connector, Conference link connector, IR Sensor, Power switch Status Output Serial port, LAN connector, Conference link connector, Power button, LEDs Power Power connector Please see User Guidance section of this document for list LEDs and description of their behavior. 1.4 Roles and Services The modules support two authorized roles (as required by FIPS 140-2) that operators may assume: a Crypto Officer role and User role. 1.4.1 Crypto-Officer Role The Crypto-Officer (CO) installs and uninstalls the cryptographic module. Also, the CO is responsible for monitoring and configuring the modules and call settings. The Crypto-Officer can manage the VSX modules over a Transport Layer Security (TLS) v1 session through a web interface. Through this interface, the Crypto-Officer is able to configure the device and setup a call, change secure mode of operation, monitor current status and perform virtually all of the management of the module. Configuration of the modules and viewing of status can be performed with a Command Line Interface (CLI) over the local serial port or remotely via Telnet over TLS. All the management and configuration capabilities are available via the VSX's web interface are also available via secure telnet over TLS. The telnet interface includes additional debug commands that are not available over the web. The Crypto-Officer has access to the following services: Table 7 - Mapping of Crypto-Officer's Services to Inputs, Outputs, Critical Security Parameters (CSPs), and Access Control Service Description Input Output CSP and Access Control Install Assemble the systems Command Result of installation None and setup network configurations Uninstall Disassemble the VSX Command Uninstalled module None system Run Self-Test Perform the self-test Command Status output None on demand Room monitoring Monitor meeting Command Status output x.509 certificate ­ Read rooms in or out of a Session key ­Read/Write call using the Web CO password ­ Read Director feature in VSX Web. Remote diagnostics Identify and correct Command Status output x.509 certificate ­ Read issues that affect the Session key ­Read/Write user's experience via CO password ­ Read VSX Web interface. Call Detail Reports Access the system's Command Modules' settings and x.509 certificate ­ Read call history using local status output Session key ­Read/Write or remote management CO password ­ Read interface. System configuration Run the system setup Command Modules' settings and x.509 certificate ­ Read wizard locally or status output Session key ­Read/Write remotely to get the CO password ­ Read system up and running. Polycom VSX 7000e and VSX 8000 Page 15 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 1.4.2 User Role Users access teleconferencing services via the LAN port (for IP calls) or the Network Interface Bay port (ISDN calls). Services provided for Users are given below in Table 8. Table 8 - Mapping of User's Services to Inputs, Outputs, CSPs, and Access Control Service Description Input Output CSP and Access Control Secured call on IP Placing secured call on Command and calling Connection established Diffie-Hellman key network IP network via LAN information pairs ­ Read port IP Encryption Key ­ Read/Write Secured call on ISDN Placing secured call on Command and calling Connection established Diffie-Hellman key ISDN via BRI/PRI information pairs ­ Read port ISDN Encryption Key ­ Read/Write 1.4.3 Authentication The modules were not tested for role-based or identity-based authentication requirement as level 1 modules. However, the modules authenticate Crypto-Officer with x.509 certificate during TLS handshake. The users do not authenticate themselves to the module. 1.5 Physical Security The VSX 7000e and VSX 8000 are multi-chip standalone cryptographic modules. The modules' hardware is composed of production-grade components and the modules are entirely enclosed in solid metal cases. These cases enclose all of the modules' internal components and serve as the cryptographic boundaries for the modules. The VSX systems were tested and found conformant to the Electromagnetic Interference/Electromagnetic Compatibility (EMI/EMC) requirements specified by 47 Code of Federal Regulations, Part 15, Subpart B, Unintentional Radiators, Digital Devices, Class A (i.e., for business use). 1.6 Operational Environment The operational environment requirements do not apply to the VSX 7000e and VSX 8000. The modules do not provide a general purpose Operating System (OS) and only allow the updating of image components after checking a Digital Signature Algorithm (DSA) signature on new software images. 1.7 Cryptographic Key Management The VSX modules implement the following FIPS-approved algorithms: · AES (CBC, OFB) - key sizes 128, 192, 256 (Cert #431) · FIPS 186-2 Appendix 3.1 PRNG (Cert #224) · Secure Hashing Algorithm (SHA-1) ­ Byte oriented (Cert #501) · TDES (CBC) 1, 2, 3 keying options (Cert #460) · DSA (verify) 1024 bits (Cert #178) Additionally, the module utilizes the following non-FIPS-approved algorithm implementation: · Diffie-Hellman (key agreement, key establishment methodology provides 80-bits of encryption strength) · RSA (key wrapping, key establishment methodology provides 80-bits of encryption strength) · Hardware Random Number Generator (RNG) ­ for seeding the FIPS-approved deterministic RNG Polycom VSX 7000e and VSX 8000 Page 16 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 The module supports the following critical security parameters: Table 9 - List of Cryptographic Keys, Cryptographic Key Components, and CSPs Key Key Type Generation / Output Storage Zeroization Use Input x.509 certificate 1024 bits RSA Generated Output in Stored in Flash Erasing the flash Authenticates the (RSA Public public key externally, input plaintext in plaintext image module during key) in plaintext TLS handshake RSA Private key 1024 bits RSA Generated Never exits the Stored in Flash Erasing the flash Authenticates the private key externally, input module in plaintext image module during in plaintext TLS handshake Diffie-Hellman 1024 bits Generated Output in Stored in Zerorized on Establishes a public key public key internally plaintext volatile reboot. session key (IP or memory ISDN Encryption Key) during H.323 negotiation Diffie-Hellman 1024 bits Generated Never exits the Stored in Zerorized on Establishes a private key private key internally module volatile reboot. session key (IP or memory ISDN Encryption Key) during H.323 negotiation Integrity Check 1024 bits DSA Generated Never exits the Stored in Flash Erasing the flash Checks integrity Key Public key externally, module in plaintext image of the software at inputted in power-up of the plaintext module Session Key 192 bits TDES Generated Exits in Held in volatile Zerorized on Encrypts TLS CBC key internally during encrypted form memory in reboot. traffic TLS handshake (RSA key plaintext. transport) IP Encryption 128 bits AES Generated Never exits the Held in volatile Zerorized on Encrypts IP calls Key CBC key internally during module memory in reboot. Diffie-Hellman plaintext. key agreement ISDN 128, 192, 256 Generated Never exits the Held in volatile Zerorized on Encrypts ISDN Encryption Key bits AES OFB internally during module memory in reboot. calls keys Diffie-Hellman plaintext. key agreement PRNG seed 20 bytes of Internally Never exits the Held in volatile Zerorized on Produce FIPS seed value generated module memory only in reboot approved random plaintext. number 1.7.1 Key Generation The modules generate symmetric keys and FIPS-approved PRNG seeds internally. The symmetric keys (Session Key, IP Encryption Key, and ISDN Encryption Key) and Diffie-Hellman key pair are generated using a FIPS- approved 186-2 Appendix 3.1 algorithm. Twenty bytes of hardware generated noise is used to create a PRNG seed, and RSA key pair is generated externally and input into the module in plaintext. 1.7.2 Key Input/Output Rivest, Shamir, Adleman (RSA) key pair is generated externally and input to the modules in plaintext. The RSA private key and DH private key never exit the module, while the public keys are output in plaintext. The Session key exits the module in encrypted form during TLS handshakes (protected within RSA key transport). The IP Encryption Polycom VSX 7000e and VSX 8000 Page 17 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Key and ISDN Encryption Key are never output from the module. Other CSPs and keys, such as the Integrity Check Key and PRNG seed are never output from the modules. 1.7.3 Key Storage The RSA public/private key pair and Integrity Check Key are stored in the modules' flash drives in plaintext form. The Session Key, IP Encryption Key, ISDN Encryption Key, DH public/private key pair, and PRNG seed are held in volatile memory in plaintext. 1.7.4 Key Zeroization The RSA key pair is zeroized by overwriting the flash image. The Session Key, IP Encryption Key, ISDN Encryption Key, Diffie-Hellman (DH) private/public key pair and PRNG seed are available only temporarily in volatile memory during video calls. These ephemeral keys and CSP are zeroized after the session is closed or whenever power is cycled. 1.8 Self-Tests The VSX 7000e and VSX 8000 perform the following self-tests at power-up: · Software integrity check using a DSA signature verification · Known Answer Tests (KATs) o AES Known Answer Test (KAT) o Triple-DES KAT o RSA pairwise consistency check o FIPS 186-2 Appendix 3.1 PRNG KAT The cryptographic modules also perform the following conditional self-tests: · Continuous RNG for FIPS 186-2 PRNG · Continuous RNG for non-approved RNG for entropy gathering If any of the power-up self-test fails, the modules log the failure, and notification is provided to Crypto Officers through serial traces. Security relevant module functionality is not provided until all self-tests are passed. In case a self-test fails, the logged trace indicates which self-test failed, and the modules display a warning message indicating the required reboot for the system. Since these messages are not available through the Secure Telnet interface before all self-tests have passed, the messages are echoed to any connected monitor screen. 1.9 Design Assurance Polycom uses automated Configuration Management (CM) of their source code modules, organizing source code into separate version-controlled depots. Polycom uses Accurev's TimeSafe® Configuration Management System to perform automated source code control. Additionally, Microsoft Visual Source Safe (VSS) version 6.0 is used to provide configuration management for the module's FIPS documentation. This CM software and Polycom's process provides access control, versioning, and logging for all module source code and documentation. Polycom VSX 7000e and VSX 8000 Page 18 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 2 Secure Operation The VSX 7000e and VSX 8000 meet Level 1 requirements for FIPS 140-2. The sections below describe how to place and keep the module in FIPS-approved mode of operation. 2.1 Crypto-Officer Guidance The Crypto-Officer is responsible for initialization and security-relevant configuration and management of the module through the web management interface, serial port from a non networked PC, or secure Telnet over TLS. Please see Polycom's Administrator's Guide for the VSX Series for more information on setting up, configuring and maintaining the modules. 2.1.1 Initialization The Crypto-Officer is responsible for putting the modules in FIPS mode of Operation, by enabling the system to automatically encrypt calls. AES encryption is a standard feature on all VSX systems. The system will be shipped by default in Non-Secure Mode. To put the modules in FIPS mode of Operation, the Crypto-Officer must: o Go to System Admin Settings System Security o Select Secure Mode o Selecting the Secure mode will result in a system reset o The change of mode from Non-Secure mode to secure mode shall initiate Crypto-Officer password change request 2.1.2 Management Following are the points of System behavior in FIPS mode of Operation: o Default password (System Serial number) or Dummy password (No password), is not allowed for 'admin' login in the secured mode. o Only https over TLS, secure telnet, and secure FTP connections are allowed in the secured mode. The standard http connections with no security will not be allowed. o Media encryption during a call (H.323/H.320) will always be set to ON (AES-Encryption ON) The following table details the port number to be used for secure applications, telnet, FTP, and https over TLS. Application Port Number TLS Telnet Debug Port 992 TLS Telnet API Port 993 TLS FTP for control Connection 990 TLS FTP for data Connection 989 TLS http 443 The Crypto-Officer is able to monitor and configure the module via the web interface (https over TLS), serial port, or via secure telnet (Telnet over TLS). Detailed instructions to monitor and troubleshoot the systems are provided in the Administrator's Guide for the VSX Series. Software upgrade is not allowed in FIPS mode of Operation. Polycom VSX 7000e and VSX 8000 Page 19 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 2.2 User Guidance The User does not have the ability to configure sensitive information on the module. They only access the secured communication functionality of the module. Users can find the basic instructions to use the VSX systems in Getting Started Guide for the VSX Series. Users are responsible for determining when to place encrypted video calls, determining when they wish to verify encryption keys with the other side on a video call, and whether they wish to hang up a video call if encryption cannot be setup or keys verified. Users may not place unencrypted calls in FIPS mode of operation. The module has several LEDs that help users to understand systems' general status. The modules have a dedicated LED at front or transparent power button light to indicate system status. Description of the LED status is described in the Table 10 below. Table 10 - LED/Power Button Light Description Model Description Modules' Status VSX 3000 (LED) Indicators are off No power to the system. VSX 5000 (LED) Green indicator blinks slowly The system is sleeping. VSX 7000e (Power Button) VSX 7000s (LED) Green indicator flashes when The system is not in a call, and is you use the remote control receiving signals from the remote control. Amber indicator flashes when The system is in a call, and is you use the remote control receiving signals from the remote control. Green indicator is on The system is ready to make a call. Amber indicator is on The system Amber indicator is on The system is in a call. is in a call. VSX 3000: Red indicator is on The system microphone is muted. VSX 5000, VSX 7000s: Mute indicator on the Polycom microphone is red VSX 7000e (Power Button) Blue indicator is on The system is connected to power VSX 8000 (Power Button) but powered off. Green indicator is on The system is powered on. Green indicator blinks The remote control has been picked up or set down. Red indicator turns on The system is powering off. momentarily Mute indicator on the Polycom The system microphone is muted. microphone is red On VSX 5000, VSX 7000e, VSX 7000s, and VSX 8000 systems, the BRI network interface lights are located on the network interface module. On the VSX 3000 system, the lights are located on the back of the system near the BRI connectors. Polycom VSX 7000e and VSX 8000 Page 20 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 Table 11 - BRI Network Interface LEDs LED Status Status Description Indicators are off · No power to the system, or · The system is not connected to the network, or · The system is not receiving a clock signal from the network, or · The system is restarting Green indicator is on · The system is receiving a clock signal from the network. Yellow indicator is on · The system is able to make a call. Green and yellow indicators are on · The system is receiving a software update, or · The system is operating normally. The PRI network interface is available for VSX 7000e, VSX 7000s, and VSX 8000 systems. Table 12 - PRI Network Interface LEDs LED Status Status Description Indicators are off No power to the system. Red indicator is on or blinking The system is not connected to the ISDN network, or there is a problem with the ISDN line. Yellow indicator is on or blinking There is a problem with the ISDN line. Green indicator is on The system is able to make and receive calls. The serial V.35/RS-449/RS-530 network interface is available for VSX 7000e, VSX 7000s, and VSX 8000 systems. Table 13 - V.35/RS-449/RS-530 Network Interface LEDs LED Status Status Description Indicators are off · No power to the system, or · The system is not communicating with the network, or · The system is restarting. Yellow indicator is on The system is receiving a clock signal from the network (able to make a call). Yellow and green indicators are Yellow and green indicators are on The system is in a call. on The system is in a call. Polycom VSX 7000e and VSX 8000 Page 21 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Non-Proprietary Security Policy, Version 1.0 June 15, 2007 3 Acronyms Table 14 - Acronyms Acronym Definition API Application Programming Interface BRI Basic Rate Interface CLI Command Line Interface CM Configuration Management CMVP Cryptographic Module Validation Program CSP Critical Security Parameter DH Diffie-Hellman DSA Digital Signature Algorithm EMC Electromagnetic Compatibility EMI Electromagnetic Interference FIPS Federal Information Processing Standard IP Internet Protocol ISDN Integrated Services Digital Network KAT Known Answer Test NIST National Institute of Standards and Technology OS Operating System PC Personal Computer PRI ISDN Primary Rate Interface RNG Random Number Generator RSA Rivest Shamir and Adleman SHA Secure Hash Algorithm TLS Transport Layer Security VSS Visual Source Safe Polycom VSX 7000e and VSX 8000 Page 22 of 22 © 2007 Polycom, Inc. - This document may be freely reproduced and distributed whole and intact including this Copyright Notice.