Brocade® DCX, DCX 8510-8, DCX-4S and DCX 8510-4 Backbones, 6510 FC Switch, 6520 FC Switch and 7800 Extension Switch with Fabric OS v7.1.0 Firmware Security Policy Document Version 1.0 Brocade Communications August 30, 2012 Copyright Brocade Communications 2012. May be reproduced only in its original entirety [without revision]. Table of Contents 1. MODULE OVERVIEW ......................................................................................................... 5   2. SECURITY LEVEL ........................................................................................................... 11   3. MODES OF OPERATION .................................................................................................. 12   APPROVED MODE OF OPERATION ................................................................................................................................... 12   NON-APPROVED MODE OF OPERATION ........................................................................................................................... 13   4. PORTS AND INTERFACES ............................................................................................... 14   LED INDICATORS ........................................................................................................................................................ 14   5. IDENTIFICATION AND AUTHENTICATION POLICY ............................................................... 15   ASSUMPTION OF ROLES ............................................................................................................................................... 15   6. ACCESS CONTROL POLICY ............................................................................................. 17   ROLES AND SERVICES.................................................................................................................................................. 17   UNAUTHENTICATED SERVICES ....................................................................................................................................... 17   DEFINITION OF CRITICAL SECURITY PARAMETERS (CSPS) ................................................................................................ 17   DEFINITION OF PUBLIC KEYS: ....................................................................................................................................... 18   DEFINITION OF CSPS MODES OF ACCESS ...................................................................................................................... 19   7. OPERATIONAL ENVIRONMENT ........................................................................................ 20   8. SECURITY RULES .......................................................................................................... 20   9. PHYSICAL SECURITY POLICY .......................................................................................... 21   PHYSICAL SECURITY MECHANISMS ................................................................................................................................ 21   OPERATOR REQUIRED ACTIONS ..................................................................................................................................... 21   10. MITIGATION OF OTHER ATTACKS POLICY ...................................................................... 21   11. DEFINITIONS AND ACRONYMS ...................................................................................... 22   12. BROCADE ABBREVIATIONS ........................................................................................... 22   APPENDIX A: TAMPER LABEL APPLICATION ......................................................................... 24   BROCADE DCX AND DCX 8510-8 BACKBONE .............................................................................................................. 24   BROCADE DCX-4S AND DCX 8510-4 BACKBONE ......................................................................................................... 28   BROCADE 6510......................................................................................................................................................... 31   BROCADE 6520......................................................................................................................................................... 33   BROCADE 7800......................................................................................................................................................... 36   Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 2 Table of Tables Table 1 Firmware Version..............................................................................................................................................5   Table 2 Switch Platforms ..............................................................................................................................................6   Table 3 Backbone Models .............................................................................................................................................7   Table 4 Supported Blades .............................................................................................................................................8   Table 5 Backbone Blade Support Matrix .....................................................................................................................9   Table 6 Module Security Level Specification ............................................................................................................ 11   Table 7 Approved Algorithms available in firmware ................................................................................................. 12   Table 8 Port/Interface Quantities .............................................................................................................................. 15   Table 9 DCX-4S, DCX, DCX 8510-4, and DCX 8510-8 blade LED counts ............................................................... 15   Table 10 Roles and Required Identification and Authentication ............................................................................ 16   Table 11 Strengths of Authentication Mechanisms ................................................................................................. 16   Table 12 Service Descriptions ................................................................................................................................... 17   Table 13 Services Authorized for Roles .................................................................................................................... 17   Table 14 CSP Access Rights within Roles & Services .............................................................................................. 19   Table 15 Public Key Access Rights within Roles & Services ................................................................................... 20   Table 16 Inspection/Testing of Physical Security Mechanisms .............................................................................. 21   Table of Figures Figure 1 DCX-4S and DCX .............................................................................................................................................9   Figure 2 DCX 8510-4 and DCX 8510-8 ..................................................................................................................... 10   Figure 3 Brocade 6510 .............................................................................................................................................. 10   Figure 4 Brocade 6520 .............................................................................................................................................. 11   Figure 5 Brocade 7800 .............................................................................................................................................. 11   Figure 6 Brocade DCX and DCX 8510-8 Backbone chassis right side seal locations ........................................... 24   Figure 7 Brocade DCX and DCX 8510-8 Backbone port side seal locations.......................................................... 25   Figure 8 Brocade DCX and DCX 8510-8 Backbone non-port side seal locations .................................................. 26   Figure 9 Brocade DCX and DCX 8510-8 Backbone flat ejector handle seal application ...................................... 26   Figure 10 Brocade DCX and DCX 8510-8 Backbone stainless steel handle seal application .............................. 27   Figure 11 Brocade DCX and DCX 8510-8 Backbone filler panel seal application ................................................. 27   Figure 12 Brocade DCX-4S and DCX 8510-4 Backbone port side seal locations.................................................. 28   Figure 13 Brocade DCX-4S and DCX 8510-4 Backbone non-port side seal locations .......................................... 29   Figure 14 Brocade DCX-4S and DCX 8510-4 Backbone flat ejector handle seal application .............................. 29   Figure 15 Brocade DCX-4S and DCX 8510-4 Backbone stainless steel ejector handle seal application ............ 29   Figure 16 Brocade DCX-4S and DCX 8510-4 Backbone filler panel (PN 49-1000294-05) seal application ...... 30   Figure 17 Brocade DCX-4S Backbone filler panel (PN 49-1000064-02) seal application ................................... 30   Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 3 Figure 18 Brocade 6510 top left port side seal application.................................................................................... 31   Figure 19 Brocade 6510 top right port side seal application ................................................................................. 31   Figure 20 Brocade 6510 bottom seal locations....................................................................................................... 32   Figure 21 Brocade 6520 left port side seal locations ............................................................................................. 33   Figure 22 Brocade 6520 right port side seal locations ........................................................................................... 33   Figure 23 Brocade 6520 top and non-port side seal locations .............................................................................. 34   Figure 24 Brocade 6520 bottom seal locations....................................................................................................... 35   Figure 25 Brocade 7800 top left port side seal locations ....................................................................................... 36   Figure 26 Brocade 7800 top right port side seal locations ..................................................................................... 36   Figure 27 Brocade 7800 bottom seal locations....................................................................................................... 37   Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 4 1. Module Overview The Brocade 6510, 6520, 7800, DCX, DCX 8510-8, DCX-4S and DCX 8510-4 are multiple-chip standalone cryptographic modules, as defined by FIPS 140-2. The cryptographic boundary for DCX, DCX 8510-8, DCX-4S and DCX 8510-4 backbone is the outer perimeter of the metal chassis including the removable cover, control processor blades, core switch blades, and port blades or filler panels. The cryptographic boundary of the 6510 FC Switch, 6520 FC Switch and 7800 Extension Switch is the outer perimeter of the metal chassis including the removable cover. The power supply units are not included in the cryptographic boundary. The module is a Fibre Channel and/or Gigabit Ethernet routing switch that provides secure network services and network management. For each module to operate in a FIPS approved mode of operation, the tamper evident seals supplied in Brocade XBR-000195 must be installed as defined in Appendix A. The security officer is responsible for storing and controlling the inventory of any unused seals. The unused seals shall be stored in plastic bags in a cool, dry environment between 60° and 70° F (15° to 20° C) and less than 50% relative humidity. Rolls should be stored flat on a slit edge or suspended by the core. The security officer shall maintain a serial number inventory of all used and unused tamper evident seals. The security officer shall periodically monitor the state of all applied seals for evidence of tampering. A seal serial number mismatch, a seal placement change, a checkerboard destruct pattern that appears in peeled film and adhesive residue on the substrate are evidence of tampering. The security officer shall periodically view each applied seal under a UV light to verify the presence of a UV wallpaper pattern. The lack of a wallpaper pattern is evidence of tampering. The security officer is responsible for returning a module to a FIPS approved state after any intentional or unintentional reconfiguration of the physical security measures. A validated module configuration is comprised of Fabric OS v7.1.0 (P/N 63-1001187-01) installed on, a switch or backbone and a set of installed blades. The below platforms may be used in a validated module configuration: Firmware Part Number Fabric OS v7.1.0 63-1001187-01 Table 1 Firmware Version Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 5 SKU Part Number Brief Description Switch 6510,24P,16GB SFP,NON-PORT2 SIDE AIR FLOW BR-6510-24-16G-F 80-1005232-031 6510,24P,16GB SFP,PORT SIDE2 AIR FLOW BR-6510-24-16G-R 80-1005267-031 6510,24P,8GB SFP,NON-PORT SIDE AIR FLOW BR-6510-24-8G-F 80-1005268-031 6510,24P,8GB SFP,PORT SIDE AIR FLOW BR-6510-24-8G-R 80-1005269-031 6510 6510,48P,16GB SFP,NON-PORT SIDE AIR FLOW, 24-PORT BR-6510-48-16G-F 80-1005271-03 POD LICENSE 6510,48P,16GB SFP, PORT SIDE AIR FLOW, 24-Port POD BR-6510-48-16G-R 80-1005272-03 LICENSE 6520, 48 port 8G, SWL SFP, non-port side exhaust. Includes BR-6520-48-8G-F 80-1007245-01 three fan FRUs and two 1100W AC power supplies 6520, 48 port 8G, SWL SFP, port side exhaust. Includes three BR-6520-48-8G-R 80-1007246-01 fan FRUs and two 1100W AC power supplies 6520, 48 port 16G, SWL SFP, non-port side exhaust. Includes 6520 BR-6520-48-16G-F 80-1007242-01 three fan FRUs and two 1100W AC power supplies 6520, 48 port 16G, SWL SFP, port side exhaust. Includes BR-6520-48-16G-R 80-1007244-01 three fan FRUs and two 1100W AC power supplies 6520, 96 port, 16G, SWL SFP, port side exhaust. Includes BR-6520-96-16G-R 80-1007257-01 three fan FRUs and two 1100W AC power supplies 80-1002607-073 BR-7800F-0001 7800,UPG LIC,22P,16 8 SWL 80-1006977-024 80-1002608-073 BR-7800F-0002 7800,UPG LIC,22P,16 8 LWL 7800 80-1006980-024 80-1002609-073 BR-7800-0001 7800,6P,8GB SWL SFP 80-1006979-024 Table 2 Switch Platforms Table 2 Notes 1. Ports 25 – 48 are physically present but disabled. A POD license is required to enable ports 25 – 48. 2. Port side and non-port side air flow indicates whether the fan direction causes air to be draw into the port side air vents or exhausted from the port side air vents. 3. Serviceable assembly 4. Production assembly. 5. Serviceable and production assemblies are functionally equivalent. The part number assigned to each production assembly was created to support the release of new agency labels with new CCC mark, humidity and altitude marks. Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 6 ` Backbone SKU Part Number Brief Description 80-1001064-101 BR-DCX-0001 DCX,2PS,0P,2CP,2 CORE,0SFP 80-1006751-012 DCX 80-1004920-041 BR-DCX-0002 DCX,2PS,0P,2CP,2 CORE,0 SFP,ENT BUN4,2 WWN 80-1006752-012 80-1002071-101 BR-DCX4S-0001 DCX-4S,2PS,0P,2CP,2 CORE,0SFP 80-1006773-012 DCX-4S 80-1002066-101 BR-DCX4S-0002 DCX-4S,2PS,0P,2CP,2 CORE,0SFP,BR,ENT BUN4 80-1006772-012 80-1004697-041, BR-DCX8514-0001 DCX8510-4,2PS,0P,2CP,2 16G CORE,0SFP 80-1006963-012 DCX 8510-4 80-1005158-041 BR-DCX8514-0002 DCX8510-4,2PS,0P,2CP,2 16G CORE,0SFP,ENT BUN4 80-1006964-012 80-1004917-041 DCX 8510-8 BR-DCX8518-0001 DCX8510-8,2PS,0P,2CP,2 16GB,0SFP,ENT BUN4 80-1007025-012 Table 3 Backbone Models Table 3 Notes 1. Serviceable assembly 2. Production assembly. 3. Serviceable and production assemblies are functionally equivalent. The part number assigned to each production assembly was created to support the release of new agency labels with new CCC mark, humidity and altitude marks. 4. Enterprise Software License Bundle: Adaptive Networking, Extended Fabrics, Advance Performance Monitoring, Trunking, Fabric Watch, Server Application Optimized Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 7 The blades listed below may be used in backbone-based validated module configurations: Acronym 4 Part Number Brief Description Blade 80-1001070-071 CP8 Control Processor Blade CP8 FRU,CP BLADE,DCX 80-1006794-012 CR16-4 80-1004897-01 FRU, CORE BLADE, DCX8510-4 CR16-4 Core Switch Blade CR16-8 80-1004898-01 FRU, CORE BLADE, DCX8510-8 CR16-8 Core Switch Blade 80-1002000-021 CR4S-8 FRU, CORE BLADE, DCX-4S CR4S-8 Core Switch Blade 80-1006771-012 80-1001071-021 CR8 FRU, CORE BLADE, DCX CR8 Core Switch Blade 80-1006750-012 FC10-6 80-1000696-01 FRU, 6-PORT 10 GBIT FC BLADE FC10-6 Port Blade FC16-32 80-1005166-02 FRU, PORT BLADE,32P,DCX8510,16G SFP FC16-32 Port Blade FC16-48 80-1005187-02 FRU,PORT BLADE,48P,DCX8510,16G SFP FC16-48 Port Blade 80-1001066-011 FC8-16 FRU, PORT BLADE, 16P, DCX, 8G SFP FC8-16 Port Blade 80-1006936-012 80-1001067-011 FC8-32 FRU, PORT BLADE, 8P, DCX, 8G SFP FC8-32 Port Blade 80-1006779-012 80-1001453-011 FC8-48 FRU, PORT BLADE, 48P, DCX, 8G SFP FC8-48 Port Blade 80-1006823-012 80-1003887-011 FC8-64 FRU, PORT BLADE, 48P, DCX, 8G SFP FC8-64 Port Blade 80-1007000-012 80-1002762-041 FCOE10-24 FRU, FCOE BLADE, 10GE X 24P FCOE10-24 Port Blade 80-1006991-012 FR4-18i 80-1000233-10 FRU, FCIP BLADE, 4G X 16P, 2X1GBE FR4-18i Port Blade 80-1002839-031 FRU, EXT BLADE, 8G X 12P, 10x1GBE, FX8-24 FX8-24 Port Blade 80-1007017-012 2X10GBE DCX/DCX 8510-8 DCX/DCX 8510-8 Filler 49-1000016-04 FILLER PANEL Filler Panel Panel DCX-4S Backbone DCX-4S Backbone Filler 49-1000064-02 FILLER PANEL Filler Panel Panel DCX-4S/DCX 8510- DCX-4S/DCX 8510-4 Filler 49-1000294-05 FILLER PANEL 4 Filler Panel Panel Table 4 Supported Blades Table 4 Notes 1. Serviceable assembly 2. Production assembly. 3. Serviceable and production assemblies are functionally equivalent. The part number assigned to each production assembly was created to support the release of new agency labels with new CCC mark, humidity and altitude marks. 4. Acronym referenced in Table 5 Backbone Blade Support Matrix Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 8 Each backbone model supports a selected set of blades: Backbone Model Blades (max count) DCX (12 slots) CP8 (2), CR8 (2), FC8-16 (8), FC8-32 (8), FC8-48 (8), FC8-64 (8), FC10-6 (1), 1 FR4-18i (4), FX8-24 (1), FCOE10-24 (1), DCX/DCX 8510-8 Filler Panel (10) DCX 8510-8 (12 slots) 1 CP8 (2) 1, CR16-8 (2), FC8-64 (8), FC16-32 (8), FC16-48 (8), FX8-24 (1), DCX/DCX 8510-8 Filler Panel (10) DCX-4S (8 slots) 1 CP8 (2) , CR4S-8 (2), FC8-16 (4), FC8-32 (4), FC8-48 (4), FC8-64 (4), FC10-6 (1), FR4-18i (4), FX8-24 (1), FCOE10-24 (1), DCX-4S Backbone Filler Panel (6), DCX-4S/DCX 8510-4 Filler Panel (6) DCX 8510-4 (8 slots) 1 CP8 (2) , CR16-4 (2), FC8-64 (4), FC16-32 (4), FC16-48 (4), FX8-24 (1), DCX-4S/DCX 8510-4 Filler Panel (6) Table 5 Backbone Blade Support Matrix Table 5 Notes 1. Each Backbone Model shall be fully populated with a minimum of two CP8 Control Processor Blades (Part Number: 80-1001070-06 or 80-1006794-01), with every remaining slot populated with a blade as per Table 5 above. The name of a backbone-based validated module configuration is formed by a concatenation of part numbers of the specific set of blades installed in the backbone. For the DCX and DCX 8510-8 platforms: …. For the DCX-4S and DCX 8510-4 platforms: …. Figure 1 DCX-4S and DCX Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 9 Figure 1 illustrates representative configurations of the DCX-4S (left image) and DCX (right image) cryptographic modules. These are not the only possible configurations. Other possible configurations can be created by utilizing the blade and support matrix information in Table 4 and Table 5. Figure 2 DCX 8510-4 and DCX 8510-8 Figure 2 illustrates representative configurations of the DCX 8510-4 (left image) and DCX 8510-8 (right image) cryptographic modules. These are not the only possible configurations. Other possible configurations can be created by utilizing the blade and support matrix information in Table 4 and Table 5. Figure 3 Brocade 6510 Figure 3 illustrates the Brocade 6510 cryptographic module. Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 10 Figure 4 Brocade 6520 Figure 4 illustrates the Brocade 6520 cryptographic module. Figure 5 Brocade 7800 Figure 5 illustrates the Brocade 7800 cryptographic module. 2. Security Level The cryptographic module meets the overall requirements applicable to Level 2 security of FIPS 140-2. Security Requirements Section Level Cryptographic Module Specification 2 Module Ports and Interfaces 2 Roles, Services and Authentication 2 Finite State Model 2 Physical Security 2 Operational Environment 2 Cryptographic Key Management 2 EMI/EMC 2 Self-Tests 2 Design Assurance 2 Mitigation of Other Attacks NA Table 6 Module Security Level Specification Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 11 3. Modes of Operation Approved mode of operation The cryptographic module supports the following Approved algorithms: Approved Algorithm Certificate Number AES 731, 1595, 1596 HMAC SHA 256 397, 933, 934 HMAC SHA 512 933, 934 HMAC SHA-1 397, 933, 934 RNG 426, 854 RSA 1048, 1049 SHS [SHA-1] 749, 1408 SHS [SHA-256] 749, 1408 SHS [SHA-512] 1407, 1408 Triple-DES 652, 1043 Table 7 Approved Algorithms available in firmware The following non-Approved algorithms and protocols are allowed within the Approved mode of operation: RSA Key Wrapping (key establishment methodology; 1024-bit keys provide 80 bits of encryption • strength) Diffie-Hellman (DH) with 1024 bit or 2048 bit modulus (key agreement; key establishment • methodology provides 80 bits of encryption strength) SNMPv3 (Cryptographic functionality does not meet FIPS requirements and is considered plaintext) • HMAC-MD5 to support RADIUS authentication • NDRNG – used for seeding Approved RNG • SSHv2 KDF • TLS KDF with HMAC-MD5 • TLS • SSHv2 • RSA Key Transport (Key establishment methodology; 1024-bit keys provide 80-bits of encryption • strength for TLS, use 2048-bit keys for SSH public key authentication) MD5 (used for password hash) • RADIUS PEAP MS-CHAP V2 • Non-deterministic random number generator for seeding ANSI X9.31 DRNG • The initial state of the cryptographic module is not in a FIPS-compliant state. The cryptographic module contains four default accounts: root, factory, admin, and user. Each default account has a public, default password. The cryptographic module may be configured for FIPS mode via execution of the following procedure: 1) Perform zeroization operation 2) Change passwords for all existing user accounts. 3) Disable Telnet, HTTP, Remote Procedure Call (RPC) Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 12 4) Enable HTTPS, Secure-RPC 5) Do not use FTP a) Config Upload b) Config Download c) Support Save d) FW Download 6) Disable Root Access 7) Disable Boot PROM Access 8) Do not use MD5 within Authentication Protocols; Diffie-Hellman with Challenge-Handshake Authentication Protocol (DH-CHAP) and FCAP. 9) Do not define FCIP IKE or IPSec policies. 10) Disable Management Interface IPSec/IKE 11) Disable In-Band Management Interface 12) Disable In-Flight Encryption 13) Disable TACACS+ authspec mode 14) Configure LDAP to use certificate-based authentication. 15) Configure SNMP Access List for read-only access. 16) Enable Self-Tests 17) Within Radius, only use PEAP MS-CHAP V2. Configure RADIUS Server to only use PEAP MS-CHAP V2. 18) Enable Signed FW Download 19) Install removable front cover (as applicable) and apply tamper labels 20) Enable FIPS mode via the “fipscfg – enable fips” command The operator can determine if the cryptographic module is running in FIPS vs. non-FIPS mode via execution of the CLI command, “fipscfg -- show” service. The module will return the following as an indicator for the FIPS Mode of Operation: “FIPS mode is: Enabled”. When operating in the Non-Approved mode of operation the following will be displayed “FIPS mode is: Disabled.” Non-Approved mode of operation In non-Approved mode, an operator will have no access to CSPs used within the Approved mode. When switching between FIPS and non-FIPS mode of operation, the operator is required to perform zeroization of the module’s plaintext CSPs. The following cipher suites are allowed in non-FIPS mode for configuring SSL and TLS: aes-128-cbc,aes-128-ecb,aes-192-cbc,aes-192-ecb,aes-256-cbc,aes-256-ecb,bf,bf-cbc,bf-cfb,bf-ecb,bf- ofb,cast,cast-cbc,cast5-cbc,cast5-cfb,cast5-ecb,cast5-ofb,des,des-cbc,des-cfb,des-ecb,des-ede,des-ede- cbc,des-ede-cfb,des-ede-ofb,des-ede3,des-ede3-cbc,des-ede3-cfb,des-ede3-ofb,des-ofb,des3,desx,rc2,rc2-40- cbc,rc2-64-cbc,rc2-cbc,rc2-cfb,rc2-ecb,rc2-ofb,rc4,rc4-40 The following message digests functions are allowed in non-FIPS mode: md2, md4, md5, rmd160 The following message authentication algorithms and ciphers are allowed in non-FIPS mode for configuring SSH: Ciphers: aes128-ctr,aes192-ctr,aes256-ctr,arcfour256,arcfour128, aes128-cbc,3des-cbc,blowfish- cbc,cast128-cbc,aes192-cbc,aes256-cbc,arcfour Macs: hmac-md5, hmac-sha1, umac-64, hmac-ripemd160, hmac-sha1-96, hmac-md5-96 Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 13 4. Ports and Interfaces The cryptographic module provides the following physical ports and logical interfaces: Fiber Channel: Data Input, Data Output, Control Input, Status Output • 1 GbE & 10 GbE: Data Input, Data Output, Control Input, Status Output • Ethernet Ports: Control Input, Status Output • Serial port: Control Input, Status Output • USB: Data Input, Data Output, Status Output • Brocade USB flash device, XBR-DCX-0131 o Power Supply Connectors: Power Input, Data Output, Status Input • LEDs: Status Output (1) • LED Indicators 1) Blades a) Blade Power LED b) Blade Status LED c) Fibre Channel port status LED d) Fibre Channel port speed LED e) USB port Status LED f) Active CP LED g) Ethernet port (SERVICE) Link LED h) Ethernet port (SERVICE) Activity LED i) Ethernet port (MGMT) Link LED j) Ethernet port (MGMT) Activity LED k) ICL port LINK LED l) ICL port ATTN LED 2) Backbone: a) WWN Status Interface LED b) FAN power LED c) FAN status LED 3) Switches: a) Switch Power LED b) Switch Status LED c) Ethernet port Link LED d) Ethernet port Activity LED e) Gigabit Ethernet (GE) port status LED f) Gigabit Ethernet (GE) port activity LED g) Fiber Channel port status LED Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 14 Port/Interface Type Fibre 1 GbE Power Model Serial Ethernet USB LED Channel & 10 Supply Port Ports GbE Connectors DCX-4S 256 24 4 2 2 2 4 DCX 512 24 4 2 2 4 30 DCX 8510-4 192 12 4 2 2 2 4 DCX 8510-8 384 12 4 2 2 4 30 6510 48 0 1 1 1 2 54 6520 96 0 1 1 1 2 107 7800 16 8 1 1 1 2 32 Table 8 Port/Interface Quantities Blade LED Blade LED CP8 Control Processor 8 FC8-16 Port Blade 18 CR16-4 Core Switch Blade 4 FC8-32 Port Blade 34 CR16-8 Core Switch Blade 4 FC8-48 Port Blade 50 CR4S-8 Core Switch Blade 6 FC8-64 Port Blade 66 CR8 Core Switch Blade 4 FCOE10-24 Port Blade 26 FC10-6 Port Blade 8 FR4-18i Port Blade 20 FC16-32 Port Blade 34 FX8-24 Port Blade 26 FC16-48 Port Blade 50 Table 9 DCX-4S, DCX, DCX 8510-4, and DCX 8510-8 blade LED counts 5. Identification and Authentication Policy Assumption of Roles The cryptographic module supports for operator roles. The cryptographic module shall enforce the separation of roles using role-based operator authentication. An operator must enter a username and its password to log in. The username is an alphanumeric string of maximum 40 characters. The password is an alphanumeric string of eight to 40 characters randomly chosen from the 96 printable and human-readable characters. Upon correct authentication, the role is selected based on the username of the operator and the context of the module. At the end of a session, the operator must log-out. The module supports a maximum of 256 operators, five Radius servers and five LDAP servers that may be allocated the following roles: Type of Authentication Role FOS RBAC Role Authentication Data Role-based operator Username and Admin (Crypto-Officer) Admin authentication Password Role-based operator Username and User, BasicSwitchAdmin, User (User role) authentication Password SwitchAdmin, Operator Role-based operator Username and Security Admin SecurityAdmin authentication Password Role-based operator Username and Fabric Admin FabricAdmin authentication Password Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 15 Type of Authentication Role FOS RBAC Role Authentication Data Maximum Permissions (for a Role -based operator Username and N/A user-defined role) authentication Password Role -based operator LDAP Root CA LDAP Server N/A authentication certificate Role -based operator RADIUS Shared RADIUS Server N/A authentication Secret Role -based operator PKI (FCAP) or Shared Host/Server/Peer Switch N/A authentication Secret (DH-CHAP) Table 10 Roles and Required Identification and Authentication Authentication Strength of Mechanism Mechanism The probability that a random attempt will succeed or a false acceptance will occur is 1/96^8 which is less than 1/1,000,000. The module can be configured to restrict the number of consecutive failed Password authentication attempts. If the module is not configured to restrict failed authentication attempts, then the maximum possible within one minute is 20. The probability of successfully authenticating to the module within one minute is 20/96^8 which is less than 1/100,000. The probability that a random attempt will succeed or a false acceptance will occur is 1/2^80 which is less than 1/1,000,000. Digital Signature The module will restrict the number of consecutive failed authentication attempts to Verification (PKI) 10. The probability of successfully authenticating to the module within one minute is 10/2^80 which is less than 1/100,000. The probability that a random attempt will succeed or a false acceptance will occur is 1/96^8 which is less than 1/1,000,000. Knowledge of a The maximum possible authentication attempts within a minute is 16. The Shared Secret probability of successfully authenticating to the module within one minute is 16/96^8 which is less than 1/100,000. Table 11 Strengths of Authentication Mechanisms Service Name Description FOS Interface Fabric element authentication, including selection of authutil Fabric Element authentication protocols, protocol configuration Authentication secauthsecret selection and setting authentication secrets. FIPSCfg Control FIPS mode operation and related functions fipscfg Zeroize Zeroize all CSPs fipgscfg --zeroize firmwarecommit FirmwareManagement Control firmware management. firmwaredownload firmwaredownloadstatus Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 16 PKI configuration functions, including FOS switch PKI seccertutil certificates and SSL certificates. RADIUS RADIUS configuration functions. aaaconfig LDAP LDAP configuration functions. aaaconfig passwd UserManagement User and password management. passwdconfig userconfig Table 12 Service Descriptions 6. Access Control Policy Roles and Services Host Server/Peer RADIUS Server SecurityAdmin FabricAdmin LDAP Server Permissions Maximum Switch Admin User Fabric Element X X X X Authentication FIPSCfg X X X Zeroize X X X FirmwareManagement X X X X X PKI X X X X X RADIUS X X X X LDAP X X X X UserManagement X X X Table 13 Services Authorized for Roles Unauthenticated Services The cryptographic module supports the following unauthenticated services: Self-tests: This service executes the suite of self-tests required by FIPS 140-2. Self-tests may be • initiated by power-cycling the module. Show Status: This service is met through the various status outputs provided by the services provided • above, as well as the LED interfaces. Definition of Critical Security Parameters (CSPs) DH Private Keys for use with 1024 bit or 2048 bit modulus • Fibre-Channel Security Protocol (FCSP) CHAP Secret • Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 17 Fibre-Channel Authentication Protocol (FCAP) Private Key (RSA 1024, 2048) • SSH/SCP/SFTP Session Keys - 128, 192, and 256 bit AES CBC or TDES 3 key CBC • SSH/SCP/SFTP Authentication Key for HMAC-SHA-1 • SSH KDF Internal State • SSH DH Shared Secret 1024 – 8192 bits • SSH 2048 RSA Private Key • TLS Private Key (RSA 1024) • TLS Pre-Master Secret • TLS Master Secret • TLS PRF Internal State • TLS Session Keys – 128, 256 bit AES CBC, TDES 3 key CBC • TLS Authentication Key for HMAC-SHA-1 • RNG Seed Material • ANSI X9.31 DRNG Internal State • Passwords • RADIUS Secret • RPC Shared Secret • Definition of Public Keys: The following are the public keys contained in the module: DH Public Key (1024 bit or 2048 bit modulus) • DH Peer Public Key (1024 bit or 2048 bit modulus) • FCAP Public Key (RSA 1024) • FCAP Peer Public Key (RSA 1024) • TLS Public Key (RSA 1024) • TLS Peer Public Key (RSA 1024) • FW Download Public Key (RSA 1024) • SSH RSA 1024/2048 bit Public Key • LDAP ROOT CA certificate (RSA 1024) • Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 18 Definition of CSPs Modes of Access Table 14 CSP Access Rights within Roles & Services defines the relationship between access to CSPs and the different module services. The modes of access shown in the table are defined as follows: R: Read • W: Write • N: No Access • Z: Zeroize • SSH/SCP/SFTP CSPs FCSP CHAP Secret Material/Internal FCAP Private Key RADIUS Secret Passwords RNG Seed TLS CSPs State Fabric Element Authentication N N RW N N RW RW FIPSCfg N N N N N N N Zeroize Z Z Z Z Z Z Z FirmwareManagement R N N N N N N PKI RW N RW N N N N RADIUS N N N RW RW N N UserManagement N RW RW RW N N N Table 14 CSP Access Rights within Roles & Services . 1024/2048 Public Download Public FCAP Public Key TLS Public Key DH Public Key LDAP Root CA Certificate Firmware SSH RSA Key Key Fabric Element Authentication RW RW N N N N FIPSCfg N N N N N N Zeroize N N N N N N FirmwareManagement N N N RW N N PKI N N RW N RW N Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 19 1024/2048 Public Download Public FCAP Public Key TLS Public Key DH Public Key LDAP Root CA Certificate Firmware SSH RSA Key Key LDAP N N N N N RW User Management N N N N N N Table 15 Public Key Access Rights within Roles & Services 7. Operational Environment The cryptographic module supports a limited operational environment; only trusted, validated code signed by RSA may be executed. 8. Security Rules The cryptographic modules’ design corresponds to the cryptographic module’s security rules. This section documents the security rules enforced by the cryptographic module to implement the security requirements of this FIPS140-2 Level 2 module. 1) The cryptographic module shall provide role-based authentication. 2) When the module has not been placed in a valid role, the operator shall not have access to any cryptographic services. 3) The cryptographic module shall perform the following tests: a) Power up Self-Tests: i) Cryptographic algorithm tests: (1) TDES CBC KAT (encrypt/decrypt) (2) AES CBC KAT (encrypt/decrypt) (3) HMAC SHA-1 KAT (4) HMAC SHA-256 KAT (5) HMAC SHA-512 KAT (6) ANSI X9.31 DRNG KAT (7) SHA-1 KAT (8) SHA-256 KAT (9) SHA-512 KAT (10) RSA 1024 SHA-1 Sign/Verify KAT ii) Firmware Integrity Test (128-bit EDC) iii) Critical Functions Tests: (1) RSA 2048 Encrypt/Decrypt KAT b) Conditional Self-Tests: i) Continuous Random Number Generator (RNG) test – performed on non-approved RNG. Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 20 ii) Continuous Random Number Generator test – performed on ANSI X9.31 DRNG. iii) RSA 1024/2048 SHA-1 Pairwise Consistency Test (Sign/Verify) iv) RSA 1024/2048 Pairwise Consistency Test (Encrypt/Decrypt) v) Firmware Load Test (RSA 1024 SHA-1 Signature Verification vi) Bypass Test: N/A vii) Manual Key Entry Test: N/A 4) At any time the cryptographic module is in an idle state, the operator shall be capable of commanding the module to perform the power-up self-test. 5) Data output shall be inhibited during key generation, self-tests, zeroization, and error states. 6) Status information shall not contain CSPs or sensitive data that if misused could lead to a compromise of the module. 7) The module does not support a maintenance role or maintenance interface. 9. Physical Security Policy Physical Security Mechanisms The multi-chip standalone cryptographic module includes the following physical security mechanisms: Production-grade components and production-grade opaque enclosure with tamper evident seals. • Tamper evident seals. • Operator Required Actions The operator is required to inspect the tamper evident seals, periodically, per the guidance provided in the user documentation. Physical Security Recommended Frequency of Inspection/Test Guidance Mechanisms Inspection/Test Details Reference Appendix A for a description of tamper label Tamper Evident Seals 12 months application for all evaluated platforms. Table 16 Inspection/Testing of Physical Security Mechanisms 10. Mitigation of Other Attacks Policy The module has not been designed to mitigate any specific attacks beyond the scope of FIPS 140-2 requirements. Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 21 11. Definitions and Acronyms 10 GbE 10 Gigabit Ethernet AES Advanced Encryption Standard Blade Any functional assembly that can be installed in a chassis, excluding power and fan FRUs CBC Cipher Block Chaining CLI Command Line interface CSP Critical Security Parameter DH Diffie-Hellman FIPS Federal Information Processing Standard FOS Fabric Operating System FRU Field Replaceable Unit GbE Gigabit Ethernet HMAC Hash Message Authentication Code HTTP Hyper Text Transfer Protocol KAT Known Answer Test LED Light Emitting Diode LDAP Lightweight Directory Access Protocol MAC Message Authentication Code NTP Network Time Protocol NOS Network Operating System PKI Public Key Infrastructure PROM Programmable read-only memory RADIUS Remote Authentication Dial In User Service RNG Random Number Generator RSA Rivest Shamir and Adleman method for asymmetric encryption SCP Secure Copy Protocol SHA Secure Hash Algorithm SSH Secure Shell Protocol TDES Triple Data Encryption Standard TLS Transport Layer Security Protocol 12. Brocade Abbreviations 24P 24 ports 48P 48 ports 16GB 16 Gigabit 8GB 8 Gigabit SFP Small form-factor pluggable LWL long wave length SWL Short wave length LIC License UPG Upgrade 2PS Two power supply modules 0P No port blades 0SFP Zero SFP devices provided Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 22 2CP Two Control processor blades (see Table 4) 2 CORE Two core switch blades (see Table 4) ENT BUN Enterprise Software License Bundle: Adaptive Networking, Extended Fabrics, Advance Performance Monitoring, Trunking, Fabric Watch, Server Application Optimized (see table note for Table 3) BR Brocade WWN World Wide Name card POD Ports on Demand, Defines the size of an upgrade license. For example, a 24-Port POD License allows the user to enable twenty-four additional ports FC Fibre Channel FCIP Fiber Channel over Internet Protocol GE Gigabit Ethernet GBE Gigabit Ethernet CP8 8G Control Processor blade CR8 8G Core Switch Blade for DCX backbone CR4S-8 8G Core Switch Blade for DCX -4S backbone CR16-8 16G core switch blade for DCX 8510-8 backbone CR16-4 16G core switch blade for DCX 8510-4 backbone FC8-16 8G, 16-port, Fibre Channel port blade FR4-18i 4G, 18 port, FCIP, routing and extension blade FCOE Fiber Channel over Ethernet FCOE10-24 10G, 24 port, FCoE blade FX8-24 8G, 24 port, Extension blade ICL Inter-Chassis Link MGMT Management Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 23 Appendix A: Tamper Label Application Use ethyl alcohol to clean the surface area at each tamper evident seal placement location. Prior to applying a new seal to an area, that shows seal residue, use consumer strength adhesive remove to remove the seal residue. Then use ethyl alcohol to clean off any residual adhesive remover before applying a new seal. Brocade DCX and DCX 8510-8 Backbone Twenty-two tamper evident seals are required to complete the physical security requirements. Apply three seals are to the right side of the chassis Figure 6 Brocade DCX and DCX 8510-8 Backbone chassis right side seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 24 Apply twelve seals are to the port side of the chassis Figure 7 Brocade DCX and DCX 8510-8 Backbone port side seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 25 Apply seven seals are to the non-port side of the chassis Figure 8 Brocade DCX and DCX 8510-8 Backbone non-port side seal locations Figure 9 Brocade DCX and DCX 8510-8 Backbone flat ejector handle seal application Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 26 Figure 10 Brocade DCX and DCX 8510-8 Backbone stainless steel handle seal application Figure 11 Brocade DCX and DCX 8510-8 Backbone filler panel seal application Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 27 Brocade DCX-4S and DCX 8510-4 Backbone Nineteen tamper evident seals are required to complete the physical security requirements. Apply fourteen seals are to the port side of the chassis Figure 12 Brocade DCX-4S and DCX 8510-4 Backbone port side seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 28 Apply five seals are to the non-port side of the chassis Figure 13 Brocade DCX-4S and DCX 8510-4 Backbone non-port side seal locations Figure 14 Brocade DCX-4S and DCX 8510-4 Backbone flat ejector handle seal application Figure 15 Brocade DCX-4S and DCX 8510-4 Backbone stainless steel ejector handle seal application Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 29 Figure 16 Brocade DCX-4S and DCX 8510-4 Backbone filler panel (PN 49-1000294-05) seal application Figure 17 Brocade DCX-4S Backbone filler panel (PN 49-1000064-02) seal application Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 30 Brocade 6510 Two tamper evident seals are required to complete the physical security requirements. Figure 18 Brocade 6510 top left port side seal application Figure 19 Brocade 6510 top right port side seal application Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 31 Figure 20 Brocade 6510 bottom seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 32 Brocade 6520 Twenty-six (26) tamper evident seals are required to complete the physical security requirements. 1. Relative to the port side of the Brocade 6520, apply four (4) seals along the left bottom side of the chassis. Make a 90 degree bend from the left side to the bottom side of the chassis. See Figure 21 for details on how to position each seal. 2. Relative to the port side of the Brocade 6520, apply one (1) seal vertically, on the left side of the switch, over the seam between the top cover and the front panel of the switch. Do not allow the seal to cover either of the rack mount screw holes on the left side of the switch. See Figure 21 for details on how to position each seal. Step 2 seal location Step 1 seal locations Figure 21 Brocade 6520 left port side seal locations 3. Relative to the port side of the Brocade 6520, apply four (4) seals along the right bottom side of the chassis. Make a 90 degree bend from the right side to the bottom side of the chassis. See Figure 22 for details on how to position each seal. 4. Relative to the port side of the Brocade 6520, apply one (1) seal vertically, on the right side of the switch, over the seam between the top cover and the front panel of the switch. Do not allow the seal to cover either of the rack mount screw holes on the left side of the switch. See Figure 22 for details on how to position each seal. Step 3 seal locations Step 4 seal location Figure 22 Brocade 6520 right port side seal locations 5. Relative to the non-port side of the Brocade 6520, apply one (1) seal over the seam between the top cover and the grill of the each of the three (3) FAN FRUs. Each seal makes a 90 bend from the top of the switch and the grill of each FAN FRU. See Figure 23A for details on how to position each seal. Apply two (2) seals over the flathead screws on the top cover near the FAN FRUs. See Figure 23A and Figure 23D for details on how to position each seal. Five (5) seals are required to complete this step. 6. Relative to the non-port side of the Brocade 6520, apply two (2) seals over the seam between the chassis and the AC power module on the left non-port side of the chassis. See Figure 23B and Figure 23D for details on how to position each seal. Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 33 7. Relative to the non-port side of the Brocade 6520, apply two (2) seals over the seam between the chassis and the AC power module on the right non-port side of the chassis. See Figure 23C and Figure 23D for details on how to position each seal. 8. Relative to the non-port side of the Brocade 6520, apply one (1) seal to the flange of each of the three (3) FAN FRUs and the bottom of the switch. Each seal makes a 90 bend from the bottom of the switch to the flange of each FAN FRU. See Figure 23D and Figure 23E for details on how to position each seal. Three (3) seals are required to complete this step. A C B D E Figure 23 Brocade 6520 top and non-port side seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 34 9. Relative to the port side of the Brocade 6520, apply four (4) seals diagonally, on the bottom side of the switch, over the seam between the front panel and the bottom panel of the switch. See Figure 24 for details on how to position each seal. Step 9 seal locations Figure 24 Brocade 6520 bottom seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 35 Brocade 7800 Two tamper evident seals are required to complete the physical security requirements. Figure 25 Brocade 7800 top left port side seal locations Figure 26 Brocade 7800 top right port side seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 36 Figure 27 Brocade 7800 bottom seal locations Brocade Communications FOS v7.1.0 Security Policy v1.0 Page 37